Fiche publication


Date publication

novembre 2009

Auteurs

Membres identifiés du Cancéropôle Est :
Dr BERNIER-CHASTAGNER Valérie , Dr QUETIN Philippe


Tous les auteurs :
Padovani L, Huchet A, Claude L, Bernier V, Quetin P, Mahe M, Laprie A, Kerr C, Bondiau PY, Delarue A, Coze C, Gibon D, Barteau C, Maire JP, Carrie C, Muracciole X

Résumé

PURPOSE: To investigate variability of clinical target volume (CTV) delineation and deviations according to doses delivered in normal tissue for abdominal tumor irradiation in children. MATERIAL AND METHODS: For a case of nephroblastoma six French pediatric radiation oncologists outlined post-operative CTV, on the same dosimetric CT scan according to the International Society for Pediatric Oncology 2001 protocol. On a reference CTV and organs at risk (OAR), we performed dosimetric planning with the constraints as 25.2 Gy for CTV, V(20 max) to 50% for liver, V(12)

Référence