Fiche publication
Date publication
février 2017
Journal
Annales de biologie clinique
Auteurs
Membres identifiés du Cancéropôle Est :
Dr LIZARD Sarab
,
Dr GOUSSOT Vincent
Tous les auteurs :
Dumont P, Goussot V, David A, Lizard S, Riedinger JM
Lien Pubmed
Résumé
The anticoagulant mostly employed for platelet count is EDTA. The Francophone Group of Cellular Hematology recommends checking of blood smear stained with May-Grünwald Giemsa any thrombocytopenia less than 100 G/L without medical history or whether an alarm is generated by the cell counter. The pseudo-thrombocytopenia (PTP) with EDTA is the best known artifact in platelet count. A sample of blood on citrated tube is necessary to get rid of the interference. The objective of this study was to compare the platelet counts obtained on EDTA (numEDTA) and citrate (numCTAD) tubes and to define, then validate a factor of conversion between both methods. The prevalence of PTP EDTA is 0.26%. The PTP was transient in 80% of the patients. The numEDTA and numCTAD+10% (numCTAD increased by 10% to take dilution into account) are correlated but are not equivalent. The numCTAD+10% underestimate numEDTA significantly. The systematic bias is removed if we increase by 17% numCTAD. The factor of correction is stable over a period of 3 hours.
Mots clés
Adult, Aged, Aged, 80 and over, Anticoagulants, pharmacology, Artifacts, Citric Acid, pharmacology, Diagnostic Errors, Edetic Acid, pharmacology, False Positive Reactions, Female, Humans, Male, Middle Aged, Platelet Count, methods, Prevalence, Thrombocytopenia, blood
Référence
Ann. Biol. Clin. (Paris). 2017 Feb;75(1):61-66