Toward standardization of BK virus monitoring: evaluation of the BK virus R-gene kit for quantification of BK viral load in urine, whole-blood, and plasma specimens.

Fiche publication


Date publication

décembre 2014

Auteurs

Membres identifiés du Cancéropôle Est :
Pr BAHRAM Siamak


Tous les auteurs :
Sueur C, Solis M, Meddeb M, Soulier E, Domingo-Calap P, Lepiller Q, Freitag R, Bahram S, Caillard S, Barth H, Stoll-Keller F, Fafi-Kremer S

Résumé

Screening of BK virus (BKV) replication is recommended to identify patients at increased risk of BKV-associated diseases. However, the heterogeneity of molecular techniques hinders the establishment of universal guidelines for BKV monitoring. Here we aimed to compare the performance of the CE-marked BK virus R-gene kit (R-gene) to the performance of our in-house assay for quantification of BKV DNA loads (BKVL). A 12-specimen panel from the Quality Control for Molecular Diagnostics (QCMD) organization, 163 urine samples, and 88 paired specimens of plasma and whole blood (WB) from transplant recipients were tested. Both the R-gene and in-house assays showed a good correlation within the QCMD panel (r = 0.995 and r = 0.989, respectively). BKVL were highly correlated between assays, although positive biases were observed with the in-house assay in analysis of urine (0.72 +/- 0.83 log10 copies/ml), plasma (1.17 +/- 0.63 log10 copies/ml), and WB (1.28 +/- 0.37 log10 copies/ml). Recalibration with a common calibrator significantly reduced the bias in comparisons between assays. In contrast, BKVL was underestimated with the in-house PCR in eight samples containing BKV genotype II, presenting point mutations at primer-annealing sites. Using the R-gene assay, plasma and WB specimens were found to be equally suitable for quantification of BKVL, as indicated by the high correlation coefficient (r = 0.965, P < 0.0001). In conclusion, the R-gene assay demonstrated reliable performance and higher accuracy than the in-house assay for quantification of BKVL in urine and blood specimens. Screening of BKV replication by a well-validated commercial kit may enable clinical laboratories to assess viral loads with greater reproducibility and precision.

Référence

J Clin Microbiol. 2014 Dec;52(12):4298-304